1. |
After disconnecting the vapor hose from the PCV valve, remove
the PCV valve.
|
2. |
Reconnect the PCV valve to the vapor hose.
|
3. |
Run the engine at idle, then put a finger over the open end of
the PCV valve and make sure that intake manifold vacuum can be felt.
|
4. |
If the vacuum is not felt inspect PCV operation, if operating
correctly clean or replace the vapor hose.
|
Operation and Leakage Check
Check all of the following items:
Component
Procedure
Brake Booster (A)
Check brake operation by applying the brakes during a test drive.
If the brak ...
Removal
1.
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
2.
Remove the rear seat (Refer to "Seat" in BD gro ...
Specifications
Item
Requirement
Remark
Rated voltage
DC 12V
Shall activate normally in these range.
Operating voltage range
DC 9 ~ 16V
...