1. |
Disconnect the battery negative terminal.
|
2. |
Remove the air duct and air cleaner assembly.
(Refer to Engine Mechanical System - "Air Cleaner")
|
3. |
Disconnect the starter cable (B) from the B terminal on the solenoid
then disconnect the connector from the S terminal (A).
|
4. |
Remove the 2 bolts holding the starter, then remove the starter
(A).
|
Description
Continuous Variable Valve Timing (CVVT) system advances or retards the
valve timing of the intake and exhaust valve in accordance with the ECM control
signal which is calculated by the engine ...
AGM Battery: Specification
Item
Specification
Model type
AGM 70L-DIN
Capacity [20HR/5HR] (AH)
70/56
Cold Cranking Amperage (A)
760 (SAE) / 610 (EN)
...
Filler-Neck Assembly Removal
1.
Open the fuel filler door, and then remove the filler-neck assembly
mounting screws (A).
2.
Disconnect the fuel filler hose (A) ...