A/C switch |
A/C pressure [kgf/cm² G (psi G) |
Vehicle speed [km/h (mph)] |
Coolant temperature [°C (°F)] |
Cooling fan speed |
OFF |
ㅡ |
V < 45 (28) |
95 ~ 100 (203 ~ 212) |
LOW |
100 (212) or above |
HIGH |
|||
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) |
LOW |
||
100 (212) or above |
HIGH |
|||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
||
ON |
P < 6 (85.3) |
All |
105 (221) or above |
HIGH |
6 (85.3) ≤ P < 12 (170.7) |
V < 45 (28) |
45 ~ 100 (113 ~ 212) |
LOW |
|
100 (212) or above |
HIGH |
|||
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) |
LOW |
||
100 (212) or above |
HIGH |
|||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
||
12 (170.7) ≤ P < 15.5 (120.5) |
V < 45 (28) |
-30 ~ 95 (-22 ~ 203) |
LOW |
|
95 (203) or above |
HIGH |
|||
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) |
LOW |
||
100 (212) or above |
HIGH |
|||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
||
15.5 (120.5) ≤ P |
All |
-30 (-22) or above |
HIGH |
Vehicle speed [km/h (mph)] |
Coolant temperature [°C (°F)] |
Cooling fan operation |
V < 45 (28) |
95 ~ 100 (203 ~ 212) or above |
On |
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) or above |
On |
80 (49.7) ≤ V |
105 (221) or above |
On |
Auto Defogging Sensor (FATC only) Description
The Auto Defogging Sensor is installed on the front windshild glass. The
Auto Defogging Sensor senses moisture on the windshild. The air conditioner
control module receives the signal from th ...
SS-B Solenoid Valve(ON/OFF) Specifications
ON/OFF Solenoid Valve(SS-A, SS-B)
▷ Control type : Normal low type
Control pressure kpa (kgf/cm², psi)
490.33(5.0, 71.12)
Internal resistance( ...
Components
1. Union bolt
2. Gasket
3. Tube joint
4. Clutch tube
5. Valve plate
6. Valve spring
7. Bleeder screw
8. Release cylinder
9. Return spring
10. Piston
11 ...