1. |
Remove the condenser.
|
2. |
Remove the cap (B) on the bottom of the condenser with L wrench
(A).
|
3. |
Remove the desiccant (A) from condenser using a long nose plier.
Check for crumbled desiccant and clogged bottom cap filter.
|
4. |
Apply air conditioning compressor oil along the O-rings and threads
of the new bottom cap.
|
5. |
Insert the new desiccant into the receiver drier tank. The desiccant
must be sealed in vacuum before it is exposed to air for use.
|
6. |
Install the new bottom cap to the condenser.
|
Line Pressure Control Solenoid Valve Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the solenoid valve connector.
3.
Measure resistance between sensor ...
Installation
1.
Install the intake CVVT (A) and exhaust CVVT (B).
Tightening torque :
63.7 ~ 73.5 N.m (6.5 ~ 7.5 kgf.m, 47.0 ~ 54.2 lb-ft)
...
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the HO2S connector.
3.
Measure resistance between the HO2S termi ...