1. |
Be sure to disconnect the battery cable from the negative (-)
terminal of the battery.
|
2. |
Never pull on the wires when disconnecting connectors.
|
3. |
Locking connectors will click when the connector is secure.
|
4. |
Handle sensors and relays carefully. Be careful not to drop them
against other parts.
|
Evaporator Temperature Sensor Description
The evaporator temperature sensor will detect the evaporator core temperature
and interrupt compressor relay power in order to prevent evaporator freezing
by excessive cooling.
...
Front Strut Assembly Components
•
Tighten with specifed torque at curb position of vehicle
•
...
Blower Motor Inspection
1.
Connect the battery voltage and check the blower motor rotation.
2.
If the blower motor does not operate well, substitute with a know ...