Warning Lamp Behavior after Ignition On |
1. |
Active fault or historical fault counter is greater or equal to
10.
|
2. |
Normal or historical fault counter is less than 10.
|
3. |
When turning the ignition switch ON during variant coding (EOL)
mode, the airbag warning lamp is turned on and blinks at intervals of
1 second till the coding is completed.
If the variant coding is completed normally, the airbag warning
lamp will turn on for 6 seconds, and then turned off. Otherwise the
airbag warning lamp continuously blinks at intervals of 1 second.
When there is active fault in airbag system or SRSCM internal
fault, the variant coding (EOL) cannot be completed. In this case, perform
the variant coding (EOL) procedure again after troubleshooting with
the GDS.
|
1. |
Loss of battery supply to the SRSCM : warning lamp turned on continuously.
|
2. |
Loss of internal operating voltage : warning lamp turned on continuously.
|
3. |
Loss of Microprocessor operation : warning lamp turned on continuously.
|
4. |
SRSCM not connected : warning lamp turned on continuously.
|
Seat Belt Buckle Switch (BS) Components
...
Rear Wiper Motor Installation
1.
Install the rubber packing.
2.
Install the rear wiper motor assembly.
Tightening torque :
6.86 ~ 9.81N ...
Inspection
1.
Connect the GDS on the Data Link Connector (DLC).
2.
Measure the output voltage of the RPS at idle and various engine
speed.
...