1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
2. |
Disconnect the variable intake solenoid valve connector (A).
|
3. |
Disconnect the vacuum hoses (B) from the valve.
|
4. |
Remove the installation bolt, and then remove the valve (C) from
the surge tank.
|
Description
Heated Oxygen Sensor (HO2S) consists of zirconium and alumina and is installed
both upstream and downstream of the Manifold Catalytic Converter. The sensor
output voltage varies in accordance ...
Specification
Temperature
Resistance (kΩ)
°C
°F
-40
-40
40.93 ~ 48.35
-20
-4
13.89 ~ 16.03
0
32
...
Installation
1.
Installation is the reverse of removal.
2.
Use a SST (09580-0U000) when installing the brake caliper assembly.
...