Item |
Specification |
|
Rated voltage |
13.5V, 90A |
|
Speed in use |
1,000 ~ 18,000 rpm |
|
Voltage regulator |
IC Regulator built-in type |
|
Regulator Setting Voltage |
External mode |
Refer to below graph |
Internal mode |
14.55 ± 0.3V |
|
Temperature Gradient |
External mode |
0 ± 3 mV / °C |
Internal mode |
-3.5 ± 2mV / °C |
Item |
Specification |
|
Rated voltage |
13.5V, 110A |
|
Speed in use |
1,000 ~ 18,000 rpm |
|
Voltage regulator |
IC Regulator built-in type |
|
Regulator Setting Voltage |
External mode |
Refer to below graph |
Internal mode |
14.55 ± 0.3V |
|
Temperature Gradient |
External mode |
0 ± 3 mV / °C |
Internal mode |
-3.5 ± 2mV / °C |
Oil Pressure Switch: Inspection
1.
Check the continuity between the terminal and the body with an
ohmmeter. If there is no continuity, replace the oil pressure switch.
2.
...
Steering Angle Sensor (Except MDPS) Description
The steering angle speed sensor detects the angle of the steering wheel
in order to which direction a user chooses.The sensor is detached on the Mutil-Function
Switch (MPS) under the steering ...
SRS Control Module (SRSCM) Variant coding
After replacing the SRSCM with a new unit, the “Variant Coding” procedure
must be performed.
1.
...