Kia Rio: Mode Control Actuator Inspection - Heater - Heating,Ventilation, Air Conditioning - Kia Rio UB 2012-2019 Service ManualKia Rio: Mode Control Actuator Inspection

1.
Turn the ignition switch OFF.
2.
Disconnect the mode control actuator connector.
3.
Verify that the mode control actuator operates to the defog mode when connecting 12V to terminal 4 and grounding terminal 3.
Verify that the mode control actuator operates to the vent mode when connecting in the reverse.


1. -
2. -
3. Vent mode
4. Defog mode
5. Sensor (+ 5V)
6. Feedback signal
7. Sensor ground

4.
Connect the mode control actuator connector.
5.
Turn the ignition switch ON.
6.
Check the voltage between terminal 6 and 7.
Specification
With auto defogging activated
Door position
Voltage (V)
Error detecting
Vent
0.9 ± 0.3
Low voltage: 0.1V or less
Bi-Level
0.9 ± 0.3
 
Floor
4.1 ± 0.3
 
Mix
4.1 ± 0.3
 
Defog
4.1 ± 0.3
High voltage: 4.9V or more

With auto defogging deactivated
Door position
Voltage (V)
Error detecting
Vent
2.5 ± 0.3
Low voltage: 0.1V or less
Bi-Level
2.5 ± 0.3
 
Floor
4.1 ± 0.3
 
Mix
4.1 ± 0.3
 
Defog
4.1 ± 0.3
High voltage: 4.9V or more

It will feedback current position of actuator to controls.
7.
If the measured voltage is not within specification, substitute with a known-good mode control actuator and check for proper operation.
8.
Replace the mode control actuator if it is proved that there is a problem with it.
Mode Control Actuator Description
The mode control actuator is located at the heater unit. It adjusts position of mode door by operating mode control actuator based on signal of A/C control unit. Pressing mode select switch ...

Mode Control Actuator Replacement
1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad. (Refer to BD group - "Crash Pad") ...

See also:

Line Pressure Control Solenoid Valve Removal
   Replacing an on/off solenoid valve (SS-A, SS-B) does not require additional hydraulic pressure adjustment; however, the ...

Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Specifications
Direct control VFS[35R/C] ▷ Control type : Normal low type Control Pressure kpa (kgf/cm², psi) 500.14 ~ 9.81 (5.1 ~ 0.1,72.54 ~ 1.42) Current value(mA ...

Oil Pan: Installation
1. Install the oil pan. (1) Using a razor blade and gasket scraper, remove all the old packing material from the gasket surfaces. ...