Kia Rio: 35R Clutch Control Solenoid Valve(35R/C_VFS) Description

Line Pressure Control Solenoid Valve Removal
35R Clutch Control Solenoid Valve(35R/C_VFS) SpecificationsDescription
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and
controls the passage between the canister and the intake manifold. It is a solenoid
valve and is open when the ECM groun ...
Specifications
Item
Requirement
Remark
Rated voltage
DC 12V
Shall activate normally in these range.
Operating voltage range
DC 9 ~ 16V
...
Thermostat: Installation
1.
Place the thermostat in the block.
Install the thermostat (B) with the jiggle valve upward.
2.
Install the water inlet fitting (A).
...