1. |
Disconnect the battery negative terminal.
|
2. |
Disconnect the air compressor connector (A) and the alternator
connector (B), and remove the cable from alternator "B" terminal (C).
|
3. |
Loosen the mounting bolts, and then turn the adjusting bolt (A)
clockwise to loosen tension.
|
4. |
Remove the drive belt (A).
|
5. |
Remove the alternator (A) after remove the mounting bolts.
|
Inhibitor Switch Circuit Diagram
...
Oil Pump Unit (OPU) Circuit diagram
...
Installation
1.
Install in the reverse order of removal.
Battery (-)terminal installation
[with battery sensor] :
4.0 ~ 6.0 N.m (0.4 ~ 0.6 kgf. ...