1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the temperature control actuator connector.
|
3. |
Verify that the temperature control actuator operates to the warm
position when connecting 12V to terminal 3 and grounding terminal 4.
Verify that the temperature control actuator operates to the cool
position when connecting in the reverse.
|
4. |
Connect the temperature control actuator connector.
|
5. |
Turn the ignition switch ON.
|
6. |
Check the voltage between terminal 6 and 5.
Specification
It will feedback current position of actuator to controls.
|
7. |
If the measured voltage is not within specification, substitute
with a known-good temperature control actuator and check for proper
operation.
|
8. |
Replace the temperature control actuator if it is proved that
there is a problem with it.
|